MV-WA0009 Desktop Thermal Printer for Weighing Tickets
video
MV-WA0009 Desktop Thermal Printer for Weighing Tickets

MV-WA0009 Desktop Thermal Printer for Weighing Tickets

Brand: METRAVON

Model: MV-WA0009

Output: Thermal paper tickets; host interface to be confirmed

Power Supply: Supply specification to be confirmed

Ingress Protection: No IP rating specified

Measuring Range: Not applicable (printer)

Description: METRAVON MV-WA0009 thermal printer uses 57 mm thermal paper rolls for weighing tickets. Confirm host compatibility, print layout and supply before requesting a quote.

Product Details

METRAVON MV-WA0009 is a desktop thermal printer for a weighing station that needs paper tickets from a compatible indicator or host. The enclosure measures 148 x 115 x 80 mm, and the specified thermal paper roll is 57 mm wide with a 45 mm diameter. Confirm the host interface and print format before ordering; paper size alone does not establish compatibility.

Match the ticket to the weighing workflow

Start with a sample ticket showing the information the operator needs. Identify which device supplies the weight, unit, tare value, time or job reference. The printer should not be assumed to calculate weights or generate transaction data that the connected system does not supply.

A load cell's millivolt signal is not a printable record. A suitable weighing instrument or host must first process the measurement and send data in a format accepted by the printer. If the project requires adhesive labels instead of paper tickets, review MV-WA0010; that is a separate media and integration choice.

Listed specificationMV-WA0009
Product typeDesktop thermal printer
Overall dimensions148 x 115 x 80 mm
Paper width57 mm
Specified roll diameter45 mm
MV-WA0009 desktop thermal ticket printer
Allow access to the paper compartment as well as space for the printer and its cables.

Approve the connection and a sample print

Provide the host model, available output port and its print-command documentation. Ask for confirmation of the supplied printer's interface, connector pinout, power requirements and any required settings. No USB, RS232, Ethernet connection or command language is promised by this listing.

Use a complete sample from the intended weighing cycle for acceptance. Check the decimal position, units, field order and legibility, including the longest required identifier. Also confirm what triggers printing and how the installation handles a repeat request, paper replacement and interrupted power. These are checks for the combined system, not claims that this model includes automatic recovery or duplicate suppression.

Ticket-printer questions

Q1. Can every 57 mm roll be used?

Not necessarily. Width is one dimension; the roll diameter, core and suitable thermal-paper specification must also be confirmed. The published roll size is 57 mm by 45 mm diameter. Do not interpret those figures as the printable width or the length of an individual ticket.

Q2. Is a thermal ticket suitable as the only long-term record?

That depends on the media and storage conditions. Thermal images can deteriorate with heat and light, so define the retention requirement and evaluate the selected paper. Where records must remain available over a long period, plan an appropriate electronic record or other retention method rather than assuming indefinite paper readability.

Q3. Can the weighing indicator power the printer?

Only if both devices' documented electrical requirements permit that arrangement. Obtain the printer supply specification and the indicator port limits; a matching connector is not sufficient evidence. Confirm whether the quotation includes the required supply and connection cable.

For an MV-WA0009 quotation, attach the host details and sample ticket, then state printing frequency, media quantity and installation environment. Specify the required character set and record fields so that a realistic sample can be checked before acceptance.