MV-WA0014 Seven-Segment Remote Weight Display: Size Options
video
MV-WA0014 Seven-Segment Remote Weight Display: Size Options

MV-WA0014 Seven-Segment Remote Weight Display: Size Options

Brand: METRAVON

Model: MV-WA0014

Output: Remote weight indication; interface to be confirmed

Power Supply: Display power requirements to be confirmed

Ingress Protection: Environmental rating requires confirmation

Measuring Range: No independent weighing range specified

Description: Compare METRAVON MV-WA0014 remote weight display sizes for weighing stations. Check mounting, site readability and indicator compatibility before requesting a quote.

Product Details

METRAVON MV-WA0014 is a seven-segment remote weight display for presenting a weighing result away from the main instrument. Four catalogue size options are available. Choose the enclosure that fits the viewing position and mounting space, then confirm that the weighing indicator can transmit a format the display accepts.

MV-WA0014 size options and installation space

Catalogue size optionOverall dimensions
1-inch254 x 100 x 41 mm
3-inch542 x 180 x 56 mm
5-inch780 x 260 x 58 mm
8-inch1000 x 500 x 70 mm

Use these dimensions to compare the space needed by each enclosure. The inch designations identify catalogue options; obtain a dimensioned drawing if the design depends on exact character height or display area. They do not establish a guaranteed reading distance.

Review the display from the operator's normal position, including likely obstructions, viewing angle and ambient light. For a loading point or vehicle approach, assess the actual sight line rather than selecting the largest enclosure automatically. Confirm mounting hardware and the support requirements before installation.

MV-WA0014 seven-segment remote weighing display
Select the size against the available mounting space and a site readability check.

Confirm what the indicator sends

A remote display shows data from a compatible instrument; it does not replace the load-cell measurement electronics. Supply the indicator model, output specification and a sample transmission where available. The connection review needs the electrical interface, data format, units and decimal placement, not just a connector photograph.

Do not infer RS485, Modbus RTU or a particular serial format from the product name. Agree the interface and settings for the supplied pair, together with the cable route and distance. If the project also needs a dot-matrix display, compare the MV-WA0015 dimensions and format-recognition limits without assuming the two models use the same connection.

Readability and operation questions

Q1. How should the remote indication be tested at commissioning?

Compare it with the main instrument across the intended operating range, including decimal position, sign and displayed unit where supported. Check how it behaves when the data connection is interrupted and restored. An old value that remains visible must not be mistaken for a current measurement; document the agreed operator response.

Q2. Is an 8-inch option automatically suitable outdoors?

No. Size alone says nothing about sealing, sunlight readability or environmental limits. Provide exposure to rain, dust, condensation and direct sun. Obtain the required protection and operating specifications before using the display outside; this listing does not establish an outdoor rating.

For MV-WA0014 pricing and connection review, send the preferred size option, indicator documentation, viewing-distance requirement, mounting photograph and quantity. Ask for the display supply specification and mounting drawing with the quotation so electrical and structural work can be planned.