Products
MV-WA0002 Embedded Thermal Label Printer, 55 x 35 mm Media
video
MV-WA0002 Embedded Thermal Label Printer, 55 x 35 mm Media

MV-WA0002 Embedded Thermal Label Printer, 55 x 35 mm Media

Brand: METRAVON

Model: MV-WA0002

Output: Thermal labels; host commands to be agreed

Power Supply: Voltage and supply requirements to be confirmed

Ingress Protection: No declared IP rating

Measuring Range: Not applicable (label printer)

Description: Assess METRAVON MV-WA0002 for panel-mounted weighing labels using 55 x 35 mm media. Check label layout, host connection and installation, then request a quotation.

Product Details

METRAVON MV-WA0002 is an embedded thermal label printer with specified 55 x 35 mm label media. It is a candidate for a weighing or packing station where the operator needs a label at the equipment panel. Begin with the label layout and the host's print capability, then check the 84.5 x 84.5 x 55.2 mm printer envelope against the installation.

Approve a label before committing to the hardware

Show the actual fields that must appear on the label, such as weight, unit and a product or batch reference. Confirm which fields come from the weighing instrument and which come from the control system. The host must supply the product information and calculated values required by the label; the printer outputs the data it receives.

The 55 x 35 mm media size is not a statement of usable print area. Have the complete layout printed on the proposed stock to check margins, line breaks and legibility. Where a barcode is required, its generation and successful scanning must be demonstrated with the intended host; barcode support is not established by the label-printer designation.

ItemListed value
Printer formatEmbedded thermal label printer
Label media55 x 35 mm
Overall enclosure84.5 x 84.5 x 55.2 mm

Specify the label stock and its handling

Supply a sample of the proposed media or its specification, including the backing and label spacing. Ask which media-sensing arrangement and roll format the supplied printer requires. The catalogue label dimensions do not establish gap sensing, black-mark sensing, roll diameter or compatibility with every adhesive stock.

MV-WA0002 embedded thermal label printer for 55 x 35 mm media
Leave room to load media and collect labels at the installed panel.

For a retrofit, compare the mounting cutout and fixing details with the existing panel. Also check the supply and host connection independently of the mechanical fit. The same overall dimensions as the MV-WA0001 paper-ticket printer do not establish electrical or media interchangeability.

Label-project questions

Q1. What should a trial run establish beyond one readable label?

Run the intended sequence long enough to check alignment over successive labels. Include media replacement and the actual trigger used by the operator or controller. Record any skipped, duplicated or misaligned labels and resolve the cause before accepting the combined printer and host configuration.

Q2. Will the label remain usable on chilled or damp packaging?

That depends on the chosen label material, adhesive and application conditions, not just the printer. Test the proposed stock on the real package surface through the required storage and handling cycle. State moisture, temperature and retention requirements when selecting the consumable.

To request a quotation for MV-WA0002, provide the finished label layout, media sample, host model, panel drawing and required quantity. Ask for the interface and supply details with the quotation so that purchasing the printer does not leave the control-panel design unresolved.

Send Form