METRAVON MV-WA0001 is an embedded thermal printer for equipment that needs a paper ticket at the operator panel. Its overall dimensions are 84.5 x 84.5 x 55.2 mm, and the specified roll is 57 mm wide with a 40 mm diameter. Plan the panel opening, paper access and host connection separately: the enclosure dimensions alone do not define an installation.
Fit the printer into the panel, not just the drawing
Obtain a mounting drawing before cutting the panel. It must identify the cutout, fixing arrangement, permitted panel thickness and rear clearance. The listed 55.2 mm depth is an overall product dimension, not a guarantee that a cabinet of that depth will accommodate connectors and cable bends.
| Published specification | MV-WA0001 |
|---|---|
| Installation type | Embedded thermal printer |
| Overall dimensions | 84.5 x 84.5 x 55.2 mm |
| Thermal roll width | 57 mm |
| Specified roll diameter | 40 mm |
Check whether an operator can open the paper compartment and remove a ticket after the printer is installed. A nearby switch, guard or cabinet door may obstruct access even when the body fits. Include the intended mounting position in the enquiry rather than approving the fit from a front-view photograph.

Prove the host can produce the required ticket
The weighing indicator or controller must supply printable data through a supported connection. Identify its exact model, available print port and command format. Request the printer's electrical supply, connector assignments and supported commands before designing the wiring. A thermal printer is not a direct input device for an analog load cell.
Prepare a sample ticket containing the required weight, unit and reference fields. Run it from the intended host, including the longest identifier and the selected decimal format. Decide whether printing is operator-triggered or controlled by the weighing sequence, then check the resulting ticket count. Do not assume that this printer provides automatic cutting, transaction numbering or data storage.
Paper and installation questions
Q1. Can a 45 mm diameter roll fit because it is also 57 mm wide?
The listed roll diameter for this model is 40 mm. A wider roll compartment must not be inferred from the common paper width. Keep the replacement media within the confirmed printer specification and check core requirements with the supplier before buying consumables in volume.
Q2. Is panel mounting sufficient protection against washdown?
No enclosure protection rating is specified here. Panel installation does not establish sealing at the printer face or paper outlet. Describe the cleaning process and exposure; obtain approval for that environment before placing the printer in a wet production area.
If the machine needs adhesive labels, assess the MV-WA0002 embedded label printer as a different media option. For a paper-ticket installation, send an MV-WA0001 enquiry with the panel drawing, host details, sample print, expected printing frequency and order quantity.