video
MV-LC0170 Compression Button Load Cell for Compact Test Fixtures

MV-LC0170 Compression Button Load Cell for Compact Test Fixtures

Brand: METRAVON

Model: MV-LC0170

Output: 2.0 +/-0.002 mV/V

Power Supply: 4-12 V DC; maximum 15 V DC

Ingress Protection: Alloy steel or stainless steel; IP67

Measuring Range: 50, 100, 250, 500, 1000 kg

Description: Evaluate METRAVON MV-LC0170 for compact compression fixtures. Check its 52 mm body, load-button contact and error limits; send your drawing for a suitable sensor quote.

Product Details

METRAVON MV-LC0170 is a low-profile compression button load cell for fixtures that apply force to a central contact. Rated-load options are 50, 100, 250, 500 and 1000 kg. Its round body and raised loading button suit a compact compression stack; it is not a beam that is fixed at one end and loaded at the other.

Fit the button load cell into the compression stack

Drawing featureDimension
Body diameter52 mm
Overall height / body height22 / 18 mm
Loading-button diameter10 mm
Mounting patternFour M5 x 0.8 holes
Hole depth / pitch-circle diameter8 / 44 mm

Check the available space with the load platen and base plate included. The platen should contact the intended central button without touching the surrounding body. Mounting screw length must suit the 8 mm hole depth and the thickness of the mating plate; a screw that bottoms out can give a false impression of a securely clamped base.

METRAVON MV-LC0170 low-profile compression button load cell
Use the central button as the load contact and keep the surrounding body clear of the platen.

Choose capacity against the force you need to distinguish

The published non-linearity is ±0.3% FS. For a 100 kg-rated version, 0.3% of full scale corresponds to 0.3 kg of rated-load equivalent. It does not mean 0.3% of every reading, and it is not a complete uncertainty statement for the test fixture. A high-capacity sensor may be unsuitable when the useful measurement is a small change near the bottom of its range.

Measurement characteristicSpecification
Rated sensitivity2.0 ±0.002 mV/V
Non-linearity±0.3% FS
Creep over 30 minutes±0.3% FS
Input / output resistance750 ±10 / 700 ±2 ohm
Excitation4-12 V DC; maximum 15 V DC
Operating temperature-10 to +40 °C
Safe overload / protection150% FS / IP67

Specify whether the task is a short compression check or a held load. For a hold test, assess the permitted change in indication during the hold as well as the initial reading. Do not interpret the 30-minute creep value as a sampling speed, response time or a limit established for every possible dwell duration.

Build the acquisition and acceptance test around the fixture

Connect the sensor to a bridge-input amplifier or weighing instrument. A PLC input expecting volts or milliamps cannot be selected from the mV/V value alone. For peak-force capture, agree the required recording interval and filtering with the instrument supplier; no bandwidth is specified here.

Check the unloaded reading after fastening the sensor, then apply a reference force through the same contact used in production. Test at the working loads, unload and repeat. If the reading depends strongly on where the platen contacts the button, correct the contact geometry before calibrating. Temperature at the sensor must stay within the stated operating range, even if the surrounding machine operates hotter.

Fixture questions

Q1. Can the base mounting holes be used to measure tension?

The holes locate and secure the body. They do not establish a tensile measurement arrangement or tensile load rating. Use this model for the defined compression contact, and select a separately documented tension-capable sensor for pulling tests.

Q2. Should the highest capacity be chosen to protect against a press crash?

Capacity selection cannot replace an engineered travel stop or machine protection. Define the normal force, credible peak and smallest required measurement change. Check the stop arrangement separately so an abnormal stroke is not simply passed into the sensor.

Send an MV-LC0170 fixture enquiry with a section through the platen and base, expected force range, hold time, sensor temperature and required recording behaviour. These details determine whether this compact geometry and error specification meet the test.