MV-LC0081 Bearing Block Load Cell: Mounting and Capacity Confirmation
video
MV-LC0081 Bearing Block Load Cell: Mounting and Capacity Confirmation

MV-LC0081 Bearing Block Load Cell: Mounting and Capacity Confirmation

Brand: METRAVON

Model: MV-LC0081

Output: 2.0 +/-0.01 mV/V reference

Power Supply: 10-12 V DC bridge excitation

Ingress Protection: Alloy steel or stainless steel; verify enclosure option

Measuring Range: 10-50 t entry; matched dimensions required

Description: Assess METRAVON MV-LC0081 for bearing reaction sensing. Resolve the capacity and mounting-table mismatch, check the bridge and request an approved assembly drawing.

Product Details

METRAVON MV-LC0081 is a bearing block load cell intended to measure the reaction beneath a bearing housing. Its technical entry states 10-50 t, but the accompanying dimensional table lists 1.5, 2.5, 4 and 10 t and uses dimension letters that do not fully match the illustrated body. Treat the drawing as an identification reference until the actual rated version and its dimensions are confirmed. It is not sufficient information for machining a replacement base.

Resolve the bearing block load cell drawing before placing the mechanical order

The outline identifies an elevated central bearing seat, two end-support regions, four central attachment holes and separate end fixings. The table alongside it does not supply a consistent dimensional definition for all of those features over the stated capacity range. Request one approved drawing showing the selected rating, all hole centres and diameters, counterbores, seat height and cable exit. Even the shared 10 t label is not enough to link a mismatched set of dimension letters to the correct body.

METRAVON MV-LC0081 reference outline with central bearing seat and separate end fixings
10-50 t technical entry; obtain the matching dimensions before approving the bearing housing, base or replacement fasteners.

Distinguish housing location from base restraint

In the described arrangement, the bearing housing attaches at the central region and the sensor ends are fixed to the base. Show how the bearing position is established and which parts resist lateral movement. Do not add a clamp over the central seat, enlarge a fixing hole or use the circular side covers as locating faces to adapt an unmatched replacement. The assembled shaft alignment and intended measuring deformation both need to be retained; fitting bolts alone does not establish that result.

ItemValueSelection notes
Technical capacity entry10-50 tRequires dimensions tied to the actual offered rating.
Dimensional-table ratings1.5 / 2.5 / 4 / 10 tNot a complete mounting definition for the 10-50 t entry.
Central seat / end supportsSeparate attachment regionsThe actual hole centres, counterbores and heights need confirmation.
Bridge sensitivity / excitation2.0 mV/V / 10-12 V DCThe listed sensitivity tolerance is +/-0.01 mV/V.
Input / output resistance750 / 700 ohmsTolerances are +/-20 and +/-5 ohms respectively.
Listed precision0.02% FSSet bearing-reaction acceptance points for the finished installation.

Review the required reaction resolution against the listed bridge data

The reference precision entry is 0.02% FS, with 0.02% FS per 10 deg C temperature effect. These are sensor entries, not a verified error for a bearing system or a computed payload. Define the reaction interval and allowable error at the working points before selecting a rating. The listed electrical channel is 2.0 +/-0.01 mV/V with 10-12 V DC excitation; its 750 +/-20 ohm input and 700 +/-5 ohm output require a suitable bridge reader, not an assumed direct current-loop connection.

Make the quotation identify both the records and the delivered scope

Provide housing and shaft drawings, expected bearing reactions, the old label and the existing indicator details. Ask for the matched dimensional release, electrical specification, installation requirements and selected enclosure configuration in the response. The offer should also state whether it includes only the sensor or any interface parts. Until those records agree, keep the base fabrication and retained-fastener approval open rather than accepting a nominal range as a complete mechanical specification.

Use acceptance to check the actual installation, not to guess the missing drawing

Once the rated configuration and installation are approved, compare known reference conditions with the final bearing housing secured and the shaft aligned. Observe repeatability, empty return and changes after an allowed alignment adjustment. A stable zero cannot confirm that the right body was supplied or that an undocumented bolt pattern is suitable. If the result feeds a protection system, its thresholds, response and fault behaviour remain a separate system-level verification.

Request MV-LC0081 with the old label, exact bearing reaction requirement, housing and base sections, and a requirement for a matched rated installation drawing.

Questions to resolve before base fabrication

Q1. Can the 10 t row be used because it overlaps the technical range?

Not without confirmation. The table and drawing use inconsistent feature definitions, so a shared capacity label alone cannot establish the hole pattern or seat geometry. Obtain a matched drawing for that exact version before machining or approving a retained base.

Q2. What can be checked while the correct drawing is being obtained?

Collect the installed label, bearing housing pattern, shaft centre height, end-support geometry, cable route and bridge-reader settings. These observations support the replacement review, but they do not replace the rated product drawing or establish compatibility. Keep dimensional approval separate from the initial enquiry.