MV-LC0002 Miniature Compression Load Cell for Compact Fixtures
video
MV-LC0002 Miniature Compression Load Cell for Compact Fixtures

MV-LC0002 Miniature Compression Load Cell for Compact Fixtures

Brand: METRAVON

Model: MV-LC0002

Output: 1.3-2.0 mV/V bridge; supplied sensitivity must be identified

Power Supply: 18 V DC maximum reference; confirm the intended bridge excitation

Ingress Protection: IP64; 17-4 PH stainless steel technical reference

Measuring Range: 8896 / 13344 / 22240 N; compression configuration to be confirmed

Description: Specify METRAVON MV-LC0002 for compact compression fixtures. Check force rating, contact area and bridge conditioning before requesting a matched sensor quotation.

Product Details

METRAVON MV-LC0002 combines a miniature compression outline with force ratings of 8896, 13344 or 22240 N. Its small diameter is an installation dimension, not evidence that a thin or uneven supporting plate is adequate. In a compact test fixture or machine force path, define the upper contact, lower support and cable exit before choosing the sensor. The approved compression arrangement determines whether the small body can measure the intended force without unintended restraint.

Build the fixture around the miniature compression load cell

The outline gives a 15.7 mm diameter, a 16.5 mm overall height reference and a 15 mm body-height reference. The top surface carries an SR101.6 curvature callout. Use the corresponding approved mating contact rather than clamping across the top and surrounding body indiscriminately. The contact profile is not a stated angular-travel allowance. Show how the force remains centred, how the base supports it and whether neighbouring parts could touch the body or bypass the load path during loading.

MV-LC0002 miniature compression outline showing 15.7 mm diameter, 16.5 mm height and side cable protection
8896, 13344 or 22240 N ratings with a 15.7 mm diameter and 16.5 mm height reference. Provide a centred compression path and room for the side cable.

Keep force units and the useful interval explicit

The three listed ratings are 8896, 13344 and 22240 N. They are discrete rated choices, not a continuous adjustment or a numerical tonne rating. State the maximum applied compression and the smallest change that the machine must resolve. Reference precision is 1% FS; selecting a larger capacity can therefore matter when the useful increment is small. Include any preload in the working-force assessment. A sensor that fits the envelope is not necessarily the right measurement range for that fixture.

Obtain the supplied bridge sensitivity and excitation

The sensitivity entry spans 1.3-2.0 mV/V without assigning one exact value to every listed force rating. Request the supplied calibration value for the chosen unit and ensure that the acquisition channel accommodates it. Input and output resistance references are 380 +/-5 and 350 +/-1 ohms. The supply entry is a maximum of 18 V DC, not a recommendation to use 18 V or a statement that any lower voltage is approved. Agree the operating excitation and use an appropriate bridge input or conditioner instead of a direct current-loop PLC input.

ItemValueSelection notes
Rated force choices8896 / 13344 / 22240 NSpecify one rating and the useful compression interval.
Diameter / full height reference15.7 / 16.5 mmAllow for the separate cable projection and mating contacts.
Bridge sensitivity reference1.3-2.0 mV/VObtain the actual supplied sensitivity for calibration.
Input / output resistance380 +/-5 / 350 +/-1 ohmsCheck excitation loading and acquisition compatibility.
Precision / supply boundary1% FS / 18 V DC maximumThe maximum supply is not a nominal-excitation instruction.
Protection / compensated intervalIP64 / -10 to +65 deg CKeep environmental protection and temperature performance explicit.

Protect the cable exit and distinguish the temperature intervals

The drawing shows side cable protection with a 33.5 mm horizontal reference beyond the body-side datum. Include that projection and the actual cable route in the available envelope. The reference cable length is 6 m; confirm it with the delivered connection record. The technical table identifies 17-4 PH stainless steel and IP64, so do not infer immersion or aggressive cleaning suitability from generic corrosion wording. Temperature compensation is -10 to +65 deg C, while operation is listed at -40 to +85 deg C. These are different limits; performance across the actual fixture temperatures needs a defined requirement.

Calibrate through the contacts that will be used in service

Apply agreed independent compression references through the final upper contact and base. Compare repeated readings and the return after unloading, including relevant preload conditions. Record the fixture parts and the supplied sensitivity so that a later replacement can be evaluated. Temperature effect is listed separately as 0.05% FS per 10 deg C. The 150% FS safe-load entry does not approve a press overload test or a fixture structural rating. Tension use needs separate mechanical approval; a general force-system description is not enough to qualify this compression arrangement.

If axial height is the limiting dimension at a lower force rating, compare the MV-LC0003 low-profile button arrangement. Its contact, rated forces and sensitivity schedule differ; the two models are not identified as interchangeable sensors.

Enquire about MV-LC0002 with the selected N rating, upper and lower contact sections, useful force increment, temperature conditions and proposed bridge acquisition.

Compact platework, sensitivity and temperature compensation

Q1. Does the small cylinder mean it can sit directly between any two plates?

The force contact and supporting surface still require approval. Provide their shape and support conditions so that force reaches the sensing body as intended rather than through an edge, housing clamp or neighbouring part.

Q2. Is the sensitivity always 2.0 mV/V?

The listed interval is 1.3-2.0 mV/V. Obtain the supplied calibration information and configure the reader for that sensor; do not assign the interval endpoint to every rating.

Q3. Can operation at -40 deg C be treated as temperature compensation down to -40 deg C?

No. The compensated interval is separately listed as -10 to +65 deg C. A project operating outside it needs an agreed performance requirement and verification at the relevant temperatures.

Send Form