MV-WM0023 Column Load Cell Weigh Module
video
MV-WM0023 Column Load Cell Weigh Module

MV-WM0023 Column Load Cell Weigh Module

Brand: METRAVON

Model: MV-WM0023

Output: Millivolt signal, confirm according to the matching sensor

Power Supply: Confirm by matching sensor

Ingress Protection: Confirm according to specific structure version

Measuring Range: Samples are not listed separately and need to be confirmed with matching sensors.

Description: MV-WM0023 is a column load cell weigh module for high-capacity tanks, silos and process vessels. Select capacity from the maximum service load and number of supports, then verify dimensions, dynamic loading and restraint. Confirm the matched load cell and final capacity when ordering.

Product Details

Key points for selection

The rated load samples are not in separate rows and need to be confirmed with supporting sensors; first determine the capacity according to the maximum load and number of supports, and then check the structural dimensions, static and dynamic loading and restraint arrangements.

Product overview

MV-WM0023 is a column load cell weigh module. The page is organized based on this single product information page and is used for procurement preliminary selection, replacement verification and project interface confirmation. Product type bellows weigh module; rated load samples are not listed separately and need to be confirmed with matching sensors; technical drawing samples include installation dimensions.

Applicable scenarios and purchasing value

For weighing retrofits on hoppers, tanks, reactors and platform equipment, the complete construction helps limit lateral movement and simplify installation. When purchasing, the number of supports, static and dynamic loading, installation foundation and pipeline additional force should be confirmed at the same time.

This page is organized according to a single product. The parameters and pictures are from the corresponding information page of the product and are not spliced with other models. Items with unclear information will be marked as order confirmation items.

Technical parameters

product typeBellows weigh module
Rated loadSamples are not listed separately and need to be confirmed with matching sensors.
technical drawingsThe sample list includes installation dimension drawings

Selection steps

  1. Determine the maximum net weight, scale body weight and number of supports
  2. Evaluate shock, vibration, eccentric loads, and additional pipeline forces
  3. Check the structure, hole location, force direction and space
  4. Matching sensors, junction boxes and instruments
  5. Confirm material, protection, temperature and explosion protection requirements

Installation and commissioning suggestions

  • The mounting surface remains flat and rigid enough
  • Prevent torque, lateral forces and welding current from passing through the sensor
  • Keep signal cables away from power lines
  • Complete segmented loading, eccentric load and zero return inspections

FAQ

How to determine the rated load of MV-WM0023?

The rated load information that can be verified on this page is: the sample is not listed separately and needs to be confirmed with the matching sensor. Also take into account the scale's own weight, maximum material volume, impact and eccentric load.

Can I place an order directly if the sample does not have a separate range?

Not recommended. The page can be used to confirm the structure and application direction. For formal orders, the supplier must confirm the capacity according to the supporting sensors, number of supports and process conditions.

Are dynamic and static load modules interchangeable?

They cannot be interchanged based on appearance alone. It is necessary to check the limit structure, impact coefficient, support method and allowable displacement. Dynamic equipment should explain the start and stop frequency and impact.

How to determine the capacity of each pivot?

Divide the sum of the scale's own weight and the maximum net weight by the number of effective fulcrums, and then consider the unbalanced load, impact and safety factor; when the center of gravity deviates significantly, it must be checked according to the most unfavorable fulcrum.

What are the installation base requirements?

The upper and lower mounting surfaces should be flat, rigid enough and the stress axis should be consistent. The module should not be allowed to bear torque, lateral force or pipeline tension for a long time.

Why does pipeline affect weighing?

Rigid pipelines, flexible connection pretension and temperature expansion and contraction will form additional forces, resulting in zero point changes and reduced repeatability, which should be released during structural design.

Do I need a junction box?

When three or four analog sensors form a system, junction box wiring and angle difference adjustment are usually required, depending on the instrument channel and angle adjustment scheme.

Can it be used outdoors or in washdown environments?

The material, protection level, cable entry and risk of water accumulation need to be checked with the specific sensor version; the structural dimension diagram itself cannot replace protection confirmation.

What are the minimum checks to do when commissioning?

The no-load zero return, segmented loading, partial load, full load and unloaded zero return inspections should be completed, and the output and calibration parameters of each fulcrum should be recorded.

What is needed for the request for quotations?

Provide maximum net weight, scale body weight, number of supports, static and dynamic loading, installation dimensions, on-site temperature, flushing or corrosion, explosion-proof requirements and supporting instruments.

Ordering instructions

When ordering, please indicate the rated load, number of supports, static and dynamic loading, installation dimensions, supporting sensors and instruments, materials, protection and explosion-proof requirements; capacities not listed separately in the sample must be confirmed in writing before placing an order.